An air-conditioning unit whose compressor is driven by a natural gas or propane engine — delivering heating, cooling and domestic hot water.
A Gas-driven Heat Pump (GHP) is an air-conditioning unit whose compressor is driven by a gas engine running on natural gas or propane. It is used for heating and cooling buildings and spaces of all kinds — boutique hotels, schools, cafeterias, restaurants, offices, villas, clinics, gyms, banks and public buildings.
AISIN is one of Toyota's largest group companies, with a very broad manufacturing portfolio. Its heat pump factory is in Japan, where it has manufactured these units for many years. The heat pumps use a gas engine developed by Toyota together with a compressor co-developed with DAIKIN.
The gas engine in the outdoor unit drives the compressor, circulating refrigerant through the system; waste heat from the engine can optionally be recovered to produce hot water as well. Indoor units are installed exactly like a conventional VRV/VRF system, and a single outdoor unit can serve multiple indoor units.
The AISIN GHP range spans 4 models from 16 HP to 30 HP; single or multi outdoor-unit combinations can be configured to match your project's needs.
| Model | AWGP 450 F1 | AWGP 560 F1 | AWGP 710 F1 | AWGP 850 F1 |
|---|---|---|---|---|
| Engine Output (HP) | 16 HP | 20 HP | 25 HP | 30 HP |
| Cooling Capacity (kW) | 45,0 | 56,0 | 71,0 | 85,0 |
| Cooling Power Consumption (kW) | 31,0 | 40,7 | 55,1 | 71,2 |
| GUE — Cooling | 1,45 | 1,38 | 1,29 | 1,19 |
| Heating Capacity (kW) | 50,0 | 63,0 | 80,0 | 95,0 |
| Heating Power Consumption (kW) | 31,7 | 42,0 | 53,6 | 68,0 |
| GUE — Heating | 1,58 | 1,50 | 1,49 | 1,40 |
| Max. Engine Waste-Heat Recovery (kW) | 16,5 | 20,0 | 25,0 | 35,6 |
| GUE — Cooling + W-Kit | 1,95 | 1,88 | 1,79 | — |
| GUE — Heating + W-Kit | 1,83 | 1,75 | 1,74 | — |
GUE (Gas Utilization Efficiency) is the gas-engine equivalent of COP: the ratio of heating/cooling energy produced to the gas energy consumed. All models use R410A refrigerant, are compatible with DAIKIN VRV indoor units, and can produce free domestic hot water with the optional W-Kit module. Hydraulic (YOSHI AWS) versions and full technical documentation are available on request.
Payback Period Based on Current Energy Prices →
Extra domestic hot water can be produced from engine waste heat, in amounts that vary with the water inlet/outlet temperature (kW).
| Model | 55/60 | 50/60 | 40/60 | 30/60 | 20/60 |
|---|---|---|---|---|---|
| 16 HP | 46,0 | 23,0 | 11,5 | 7,7 | 5,7 |
| 20 HP | 57,5 | 28,7 | 14,4 | 9,6 | 7,2 |
| 25 HP | 71,8 | 35,9 | 18,0 | 12,0 | 9,0 |
W-Kit heat recovery: engine waste heat is used for domestic hot water, building heating and AHU pre-heating
Equipped with variable-capacity scroll-type compressors, delivering higher efficiency across the entire operating range.
Exhaust gas and engine heat are easily recovered via an add-on module; the resulting hot water can be used for domestic hot water, heating and ventilation circuits, reducing operating costs.
Runs on ~75% air in both heating and cooling mode, with performance boosted by recovering free exhaust and engine heat.
Each GHP can deliver up to 40% CO2 emission savings compared with a standard heat-generation unit of the same capacity.
A subset of the VRV system using R410A refrigerant; systems can be built from 45kW–170kW outdoor units combined with indoor units of varying capacities.
Requires only single-phase, low-capacity electricity, eliminating the need for extra cabling, panels or generators — cutting electricity consumption by up to 90%.
The "Combination Multi" model pairs two outdoor units on a single refrigerant circuit up to 50 HP, reducing installation costs.
With the YOSHI AWS air-to-water unit, hydronic systems can run in variable-capacity mode in addition to simple on/off operation.
Unlike electric heat pumps, capacity does not drop at low outdoor temperatures, removing the need for a backup boiler.
Backed by a purpose-built Toyota engine with an expected service life beyond 40,000 hours; maintenance intervals of 6,000–10,000 hours.
Refrigerant systems: runs on R410A and communicates directly with DAIKIN indoor units. Hydronic systems: paired with a YOSHI AWS unit, with no brand restriction on indoor units.
Gas Systems (VRV/VRF)
Water Systems (AWS)
4-way cassette, 1-way cassette, ceiling-suspended, wall-mounted, floor-standing, slim concealed ceiling and high static pressure duct units; plus VAM/VKM fresh-air units and hotel duct types — an indoor-unit range for every kind of space.
Once you contact us, we first determine the required unit capacity together. If you have your own project engineer or firm, we provide them with the necessary design data. If not, our technical team follows through the required project work after a contract based on a budget proposal.
It is an air-conditioning unit whose compressor is driven by a gas engine running on natural gas or propane.
Heating and cooling of buildings and spaces. It suits a wide range of uses: boutique hotels, schools, cafeterias, restaurants, offices, villas, clinics, gyms, banks and public buildings.
AISIN is one of Toyota's largest group companies. Its heat pump factory is in Japan; the units use a gas engine developed by Toyota together with a compressor co-developed with DAIKIN.
It is one of the most economical and compact ways to get both heating and cooling from natural gas, at an A++ energy-efficiency level.
It can be used comfortably in both new and existing buildings.
On gas-type installations it runs on R410A refrigerant and communicates directly with DAIKIN indoor units. On hydraulic systems it is paired with the YOSHI AWS device.
The engine, developed specifically by Toyota, requires periodic servicing every 6,000–10,000 hours.
Old and new hydraulic systems are connected by installing a YOSHI device alongside the AISIN GHP. There is no brand restriction on indoor units — it is an easy, practical solution.
Once you contact us, we first determine the required capacity together. If you have your own project engineer or firm, we provide them with the necessary design data; if not, our technical team follows through and completes the project work after a contract based on the budget proposal.
Calculate this AISIN GHP model's annual running-cost savings versus an equivalent electric system (EHP/VRV), and how many years it takes for the extra investment to pay back.
Whether it's a heating-cooling solution for a new building, on-site power with micro-CHP, or EV charging infrastructure — tell us what you need.